MINIVAP ON-LINE

Save Your Money On-Line

On-line Product Quality & Compliance Monitoring for Vapor pressure of Gasoline, Crude Oil, Butane, LPG
ASTM D 5191 - DVPE of Gasoline
ASTM VPCRx - Proposed RVPE of Crude Oil
ASTM D 5188 - V/L-Ratio: T (V/L=20)
ASTM D 1267 - Vapor Pressure of LPG
5 Minutes Test Cycle Time
Automatic Calibration
Explosion Proof-Class I


Vapor Pressure of Gasoline Butane, LPG and Crude Oil The measuring principle is based on the triple expansion method of the worldwide approved and accepted MINIVAP VPS and VPSH – our portable vapor pressure testers for gasoline and crude oil. The minimum measuring cycle time is 5 minutes.

Vapor-Liquid Ratio Temperature A small amount of the pressurized sample is introduced into the chamber and expanded to the final volume. The nominal pressure is adjusted by varying the temperature of the measuring cell to obtain T(V/L=20).

Vapor Pressure of LPG The measured results are equivalent to ASTM D 1267. The sample is drawn-in by a piston and after closing the sample inlet valve, a single expansion leads to the nominal V/L-ratio.

Increase Your Profits! Using our method improves the quality of your measurement. The innovative measuring technique leads to an improved accuracy to blend 1.5 kPa (0.2 psi) closer to the limit.This small difference saves approximately US$ 400,000 a year, for a small 100,000 barrel refinery. With this annual savings, the MINIVAP ON-LINE pays for itself within two months. As incredible as this sounds, the results are field-proven!

Fiber-Optics Data Transfer The data can be transferred safely via fiber-optics either to a standard printer or to a central controller outside the explosion sensitive area. In the central controller, the vapor pressure data are displayed and complete remote control of the measuring system is feasible. The unit accommodates two RS 232 interfaces, 16 independent inputs and outputs, and an analog output.

Automatic Calibration A fully automatic calibration of the measuring unit is performed with a vapor pressure measurement of neo-hexane, or other standard liquids. It can either be started manually or automatically in programmable intervals.

TECHNICAL DATA

Temperature range: 30° to 60°C (86°F to 140°F)

Pressure range:
Gasoline:
LPG:
0 to 300.0 kPa, 0 to 45.00 psi
0 to 1000.0 kPa, 0 to 150.00 psi

Power requirements: 100/120/230/240 V AC
50/60 Hz, 65 W

Physical dimensions: 580 x 1060 x 260 mm
23.7 x 43.3 x 10.6 inches

Weight: 50 kp (110 pounds)

Click here for Technical Documentation in PDF Format